D. Reversible Flue Collar and Horizontal Flue
Heat Shield
Tools Required: #2 & #3 Phillips head screwdriver; 1/2"
wrench
The fl ue collar is reversible for either a top or rear venting
installation. The appliance is shipped with the fl ue collar in
the top vent position.
Converting Collar For Rear Vent Installation
and
Installing Required Horizontal Flue Shield
1. Remove fl ue collar (#3 Phillips) and convection chamber
top (#2 Phillips).
2. Remove 1 bolt from each side of the fl ue transition and
retrieve nuts attached to bolts.
3. Turn fl ue transition to horizontal position. Inspect rope
gasketing to ensure a leak free seal. Re-attach.
4. Remove upper fl ue cover from convection chamger top.
Rotate 180 degrees and reassebmle. Use paint supplied
to cover unpainted areas.
5. Reattach convection chamber top to fl ue collar to unit.
November 7, 2014
Figure 17.1
Figure 17.2
Figure 17.3 - Completed View
7061-197D
Explorer II Medium Wood Stove
Flue collar
Flue transition
Upper flue cover
Convection
chamber top