D. Reversible Flue Collar and Horizontal Flue
Heat Shield
Tools Required: #2 & #3 Phillips head screwdriver; 1/2"
wrench
The flue collar is reversible for either a top or rear venting
installation. The appliance is shipped with the flue collar in
the top vent position.
Converting Collar For Rear Vent Installation
and
Installing Required Horizontal Flue Shield
1. Remove flue collar (#3 Phillips) and convection chamber
top (#2 Phillips).
2. Remove 1 bolt from each side of the flue transition and
retrieve nuts attached to bolts.
3. Turn flue transition to horizontal position. Inspect rope
gasketing to ensure a leak free seal. Re-attach.
4. Remove upper flue cover from convection chamger top.
Rotate 180 degrees and reassebmle. Use paint supplied
to cover unpainted areas.
5. Reattach convection chamber top to flue collar to unit.
February 18, 2014
Explorer II Medium Wood Stove
Figure 17.1
Figure 17.2
Figure 17.3 - Completed View
7061-197B
Flue collar
Convection
chamber top
Flue transition
Upper ue cover
17