Clearances To Combustibles - Quadra-Fire EXPLRMED-PBK Instruction Manual

Explorer ii medium wood stove
Hide thumbs Also See for EXPLRMED-PBK:
Table of Contents

Advertisement

Explorer II Medium Wood Stove
B. Clearances to Combustibles
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches & (Millimeters)
NOTE: All A, B, and C Dimensions are to the center of the flue collar
INSTALLATION: FULL VERTICAL OR ALCOVE
For alcove only: Six inch diameter listed Double wall air insulated connector
pipe with UL103 HT listed factory built Class A chimney or masonry chimney.
Maximum depth of Alcove shall be no more than 48 inches (1220mm) with a
minimum height of 48 inches (1220mm) to top of unit and the referenced
clearances. Canada must comply with CAN/ULC-S269 M87 for the 650° factory
SINGLE WALL PIPE
Explorer II
DOUBLE WALL PIPE
Explorer II
* FOLLOW PIPE MANUFACTURES CLEARANCES AS REQUIRED
ALCOVE TOP VIEW
HORIZONTAL THROUGH WALL
TOP AND SIDE VIEW
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
8
A
B
built chimney
10.5 (267)
20.25 (514)
9.38 (238)
20.25 (514)
ALCOVE SIDE VIEW
B
20.25
(514)
50
(1270)
C
D
13.5 (343)
55 (1397)
10.5 (267)
55 (1397)
D
A
MANTEL
12" MAX
12
(305)
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house fi re.
7061-197D
BACKWALL / SIDEWALL
A
B
CORNER INSTALLATION
C
C
*
STOVE TO CEILING
D
CLEARANCE
WARNING
November 7, 2014

Advertisement

Table of Contents
loading

Table of Contents