90% up to 96% gas furnace units
Hide thumbs Also See for ComfortNet ACVC9:
Table of Contents

Advertisement

PRODUCT DESIGN
MODEL
GMVC950453BX*
GMVC950704CX*
AMVC950453BX*
AMVC950704CX*
GMVC950905CX*
AMVC950905CX*
GMVC950905DX*
GMVC951155DX*
AMVC950905DX*
AMVC951155DX*
GCVC950714CX*
ACVC950714CX*
GCVC950915DX*
ACVC950915DX*
GCVC91155DX*
ACVC951155DX*
(1) Dat a given is least negative pressure required for pressure switch to close.
(2) Dat a given is least negative pressure required for pressure switch to remain closed.
Not e: The typical sea level negative pressure data represent s the minimum pressures expected. S hort er length of flue pipe or single pipe systems compared to
dual pipe systems should show higher (greater negat ive) press ures.
PRESSURE SWITCH TRIP POINTS AND USAGE CHART
NEGATIVE PRESSURE
NEGATIVE PRESSURE
ID BLOWER
WITH FLUE
NOT FIRING
TYPICAL SEA LEVEL
TYPICAL SEA LEVEL
(1)
DATA
LOW FIRE
HIGH FIRE
LOW FIRE
-0.45
-0.92
-0.75
-1.60
-0.65
-1.27
-0.95
-1.80
-0.95
-1.80
-0.35
-0.70
NEGATIVE PRESSURE
ID BLOWER
WITH FLUE
FIRING
TYPICAL S EA LEVEL
(2)
DATA
HIGH FIRE
LOW FIRE
-0.30
-0.75
-0.25
-.060
-1.40
-0.25
-0.50
-1.10
-0.25
-0.80
-1.60
-0.25
-0.80
-1.60
-0.25
-0.20
-0.55
-0.52
NEGATIVE PRESSURE
COIL COVER
COIL COVER
WITH FLUE
WITH FLUE
NOT FIRING
TYPICAL SEA LEVEL
(1)
DATA
HIGH FIRE
LOW FIRE
-0.25
-0.10
-0.25
-0.10
-0.25
-0.10
-0.25
-0.10
-0.25
-0.10
-0.52
-0.37
FIRING
(2)
DATA
HIGH FIRE
-0.10
-0.10
-0.10
-0.10
-0.10
-0.37