Goodman ComfortNet ACVC9 Technical Manu Technical Manualal page 20

90% up to 96% gas furnace units
Hide thumbs Also See for ComfortNet ACVC9:
Table of Contents

Advertisement

BLOWER PERFORMANCE SPECIFICATIONS
GCVC951155DX Cooling/Heating Speed Charts
GCVC91155DX*
ACVC951155DX*
Cooling Speeds
(@.1" -.8" w.c. ESP)
Tap
Adjust
Minus 10%
Minu s 5%
Normal
A
Plus 5%
Plus 10%
Minus 10%
Minu s 5%
B
Normal
Plus 5%
Plus 10%
Minus 10%
Minu s 5%
C
Normal
Plus 5%
Plus 10%
Minus 10%
Minu s 5%
D
Normal
Plus 5%
Plus 10%
1.
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
2.
For most jobs, about 400 CFM per ton when cooling is desirable.
3.
Do not operate above .5" w.c. ESP in heating mode. Operating CFM between .5" and .8" w.c. is tabulated for cooling purposes only.
4.
Continuous fan speeds of 25%, 50%, 75% of maximum cooling airflow are available when using a communicating thermostat and 25%, 50%, 75%, 100%
of maximum cooling airflow are available in legacy mode by setting dip switches
20
High-Stage
Low-Stage
CFM
CFM
457
705
744
483
783
508
822
533
861
559
982
621
656
1,036
1,091
690
1,146
725
1,200
759
1,265
815
861
1,336
906
1,406
951
1,476
1,547
997
1,049
1,628
1,719
1,107
1,165
1,809
1,223
1,899
1,282
1,990
GCVC91155DX*
ACVC951155DX*
He ating Speeds
(@.1" -.5" w.c. ESP; Rise Range: 40 - 70°F)
High-Stage
Tap
Adjust
CFM
Minus 10%
1,583
Minus 5%
1,671
Normal
1,759
A
Plu s 5%
1,847
Plus 10%
1,935
Minus 10%
1,612
Minus 5%
1,701
B
Normal
1,791
Plu s 5%
1,881
Plus 10%
1,970
Minus 10%
1,654
Minus 5%
1,746
C
Normal
1,838
Plu s 5%
1,930
Plus 10%
2,022
Minus 10%
1,690
Minus 5%
1,784
D
Normal
1,878
Plu s 5%
1,972
Plus 10%
2,066
Low-Stage
Rise
CFM
1,093
63
1,153
59
1,214
56
1,275
53
1,335
51
1,106
61
1,168
58
1,229
55
1,290
52
1,352
50
1,166
60
1,231
57
1,296
54
1,361
51
1,426
49
1,172
59
1,237
56
1,302
53
1,367
50
1,432
48

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents