Goodman ComfortNet ACVC9 Technical Manu Technical Manualal page 15

90% up to 96% gas furnace units
Hide thumbs Also See for ComfortNet ACVC9:
Table of Contents

Advertisement

FURNACE SPECIFICATIONS
MODEL
BTUH
Natural Gas Input (High Fire)
Natu ral Gas Output (Hig h Fire)
LP Gas Input (High Fire)
LP Gas Output (High Fi re)
A.F.U.E.
Rated External Static (" w.c.)
Temperature Rise (°F)
ID Blower Pressure Switch High Fire Trip Point (" w.c.)
Front Cover Pressure Switch Trip Point (" w.c.)
Blower Wheel (D" x W")
Blower Horsep ower
Blower Speeds
Max CFM @ 0.5 E.S.P.
Power Supply
Minimum Circuit Ampacity (MCA)
Maximum Overcurrent Device
Transforme r (VA)
Primary Limit Setting (°F)
Auxiliary Limit Setting (°F)
Rollout Limit Setting (°F)
Fan Delay On Heating
(3)
Off Hea ting
Fan Delay On Cooling
Off Coo ling
Gas Supp ly Pressure (Natura l/Propane) ("w.c.)
Manifold Pressure (Natural/Pro pane) ("w.c.)
Orifice Size (Natural/Propane)
Number of Burners
Vent Con nector Diameter (inches)
Combustion Air Connector Diameter (in ches)
Shippi ng Weight (lbs.)
NOTE: Lo w fire in put is 70% of high fir e inp ut
1.
These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
2.
For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice
changes should only be made if necessary for altitude.
3.
The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the
"A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total
heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times
output.
4.
Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
GCVC91155
1 13,000
1 05,100
1 01,700
94,600
93.0%
.20 - .50
40 - 70
11 x 1 0
115-60-1
(1 )
(2)
30 secs.
150 secs.
45 secs.
3.5 / 10
43 / 55
(4)
(5)
ACVC951155
*CVC950714
DX*
DX*
113,000
105,100
101,700
94,600
93.0%
.20 - .50
40 - 70
-0 .55
-0.55
-0 .37
-0.37
11 x 10
1
1
Re fer to Blower CFM Charts
115-60-1
14.4
14 .4
15.0
15 .0
40
40
145
145
120
120
210
210
30 secs.
150 secs.
5 sec
5 sec
45 secs.
7 / 11
7 / 11
3.5 / 10
43 / 55
5
5
2
2
2
2
160
160
A/GCVC9
*CVC950915
CX*
DX*
68,000
90,000
64,600
85,500
61,200
81,000
58,100
77,000
95.0%
95.0%
.20 - .50
.20 - .50
25 - 55
25 - 55
-1.60
-1.60
-0.10
-0.10
10 x 10
11 x 10
3/4
1
1 15-60-1
115-60-1
11.2
15.0
15.0
15.0
40
40
150
13 0
120
12 0
210
21 0
30 secs.
30 secs.
150 secs.
150 secs.
5 sec
5 sec
45 secs.
45 secs.
7 / 11
7 / 11
3 .5 / 10
3.5 / 10
43 / 55
43 / 55
3
4
2
2
2
2
139
15 8
15