BLOWER PERFORMANCE SPECIFICATIONS

*MVC950453BX Cooling/Heating Speed Charts
*MVC950453BX
Cooling Speed
( @ .1" - .8" w.c. ESP)
Tap
Adjust
Minus 10%
Minus 5%
A
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
B
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
C
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
D
Normal
Plus 5%
Plus 10%
*MVC950704CX Cooling/Heating Speed Charts
*MVC950704CX
Cooling Speed
( @ .1" - .8" w.c. ESP)
Tap
Adjust
Minus 10%
Minus 5%
A
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
B
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
C
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
D
Normal
Plus 5%
Plus 10%
1.
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
2.
For most jobs, about 400 CFM per ton when cooling is desirable.
3.
Do not operate above .5" w.c. ESP in heating mode. Operating CFM between .5" and .8" w.c. is tabulated for cooling purposes only.
4.
Continuous fan speeds of 25%, 50%, 75% of maximum cooling airflow are available when using a communicating thermostat and 25%, 50%, 75%, 100%
of maximum cooling airflow are available in legacy mode by setting dip switches
16
High-Stage
Low-Stage
CFM
CFM
540
351
570
371
600
390
630
410
660
429
720
468
760
494
800
520
840
546
880
572
900
585
950
618
1,000
650
1,050
683
1,100
715
1,080
702
1,140
741
1,200
780
1,260
819
1,320
858
High-Stage
Low-Stage
CFM
CFM
540
351
570
371
600
390
630
410
660
429
720
468
760
494
800
520
840
546
880
572
990
644
1,045
679
1,100
715
1,155
751
1,210
787
1,286
836
1,358
883
1,429
929
1,500
975
1,572
1,022
*MVC950453BX
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 30 - 60°F)
High-Stage
Tap
Adjust
CFM
Minus 10%
713
Minus 5%
752
A
Normal
792
Plus 5%
832
Plus 10%
871
Minus 10%
778
Minus 5%
821
B
Normal
864
Plus 5%
907
Plus 10%
950
Minus 10%
842
Minus 5%
889
C
Normal
936
Plus 5%
983
Plus 10%
1,030
Minus 10%
907
Minus 5%
958
D
Normal
1,008
Plus 5%
1,058
Plus 10%
1,109
*MVC950704CX
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 30 - 60°F)
High-Stage
Tap
Adjust
CFM
Minus 10%
1,089
Minus 5%
1,150
A
Normal
1,210
Plus 5%
1,271
Plus 10%
1,331
Minus 10%
1,193
Minus 5%
1,259
B
Normal
1,325
Plus 5%
1,391
Plus 10%
1,458
Minus 10%
1,296
Minus 5%
1,368
C
Normal
1,440
Plus 5%
1,512
Plus 10%
1,584
Minus 10%
1,400
Minus 5%
1,477
D
Normal
1,555
Plus 5%
1,633
Plus 10%
1,711
Low-Stage
Rise
CFM
(°F)
495
57
523
49
550
41
578
43
605
46
540
52
570
49
600
47
630
45
660
43
585
48
618
45
650
43
683
41
715
39
630
45
665
42
700
40
735
38
770
36
Low-Stage
Rise
CFM
(°F)
756
56
798
53
840
50
882
48
924
46
828
51
874
48
920
46
966
44
1,012
42
900
47
950
44
1,000
42
1,050
40
1,100
38
972
43
1,026
41
1,080
39
1,134
37
1,188
35

Hide quick links: