BLOWER PERFORMANCE SPECIFICATIONS
*CVC950714CX Cooling/Heating Speed Charts
*CVC950714CX
Cooling Speeds
( @ .1" - .8" w.c. ESP)
Tap
Adjust
Minus 10%
Minus 5%
A
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
B
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
C
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
D
Normal
Plus 5%
Plus 10%
*CVC950915DX Cooling/Heating Speed Charts
Cooling Speeds
( @ .1" - .8" w.c. ESP)
Tap
Adjust
Minus 10%
Minus 5%
A
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
B
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
C
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
D
Normal
Plus 5%
Plus 10%
1.
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
2.
For most jobs, about 400 CFM per ton when cooling is desirable.
3.
Do not operate above .5" w.c. ESP in heating mode. Operating CFM between .5" and .8" w.c. is tabulated for cooling purposes only.
4.
Continuous fan speeds of 25%, 50%, 75% of maximum cooling airflow are available when using a communicating thermostat and 25%, 50%, 75%, 100%
of maximum cooling airflow are available in legacy mode by setting dip switches
High-Stage
Low-Stage
CFM
CFM
594
324
627
342
660
360
693
378
726
396
747
468
789
494
830
520
872
546
913
572
1,017
702
1,074
741
1,130
780
1,187
819
1,243
858
1,314
864
1,387
912
1,460
960
1,533
1,008
1,606
1,056
*CVC950915DX
High-Stage
Low-Stage
CFM
CFM
729
504
770
532
810
560
851
588
891
616
999
666
1,055
703
1,110
740
1,166
777
1,221
814
1,287
828
1,359
874
1,430
920
1,502
966
1,573
1,012
1,674
1,071
1,767
1,131
1,860
1,190
1,953
1,250
2,046
1,309
*CVC950714CX
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 25 - 55°F)
High-Stage
Tap
Adjust
CFM
Minus 10%
1,107
Minus 5%
1,169
A
Normal
1,230
Plus 5%
1,292
Plus 10%
1,353
Minus 10%
1,215
Minus 5%
1,283
B
Normal
1,350
Plus 5%
1,418
Plus 10%
1,485
Minus 10%
1,323
Minus 5%
1,397
C
Normal
1,470
Plus 5%
1,544
Plus 10%
1,617
Minus 10%
1,440
Minus 5%
1,520
D
Normal
1,600
Plus 5%
1,680
Plus 10%
1,760
*CVC950915DX
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 25 - 55°F)
High-Stage
Tap
Adjust
CFM
Minus 10%
1,458
Minus 5%
1,539
A
Normal
1,620
Plus 5%
1,701
Plus 10%
1,782
Minus 10%
1,575
Minus 5%
1,663
B
Normal
1,750
Plus 5%
1,838
Plus 10%
1,925
Minus 10%
1,674
Minus 5%
1,767
C
Normal
1,860
Plus 5%
1,953
Plus 10%
2,046
Minus 10%
1,773
Minus 5%
1,872
D
Normal
1,970
Plus 5%
2,069
Plus 10%
2,167
Low-Stage
Rise
CFM
783
77
827
73
870
69
914
66
957
63
855
71
903
68
950
64
998
61
1,045
58
936
65
988
61
1,040
58
1,092
55
1,144
53
1,017
59
1,074
56
1,130
53
1,187
51
1,243
49
Low-Stage
Rise
CFM
1,008
80
1,064
76
1,120
72
1,176
68
1,232
65
1,098
73
1,159
69
1,220
66
1,281
63
1,342
60
1,152
70
1,216
66
1,280
63
1,344
60
1,408
57
1,206
67
1,273
63
1,340
60
1,407
57
1,474
55