Install Vent System; Level Dryer - Whirlpool LEW0050PQ Job Aid And Service Manual

24" electric dryer
Hide thumbs Also See for LEW0050PQ:
Table of Contents

Advertisement

2.
Determine vent length. The maximum
length of the exhaust system depends
upon:
• The type of vent (rigid metal or flexible
metal).
• The number of elbows used.
• Type of hood.
Recommended hood styles are shown
here.
A
4"
(10.2 cm)
A. Louvered style
B. Box hood style
The angled hood style (shown following)
is acceptable.
4"
(10.2 cm)
See the exhaust vent length chart that
matches your hood type for the maximum
vent lengths you can use.
Exhaust systems longer than specified
will:
• Shorten the life of the dryer.
• Reduce performance, resulting in
longer drying times and increased en-
ergy usage.
3.
Determine the number of elbows you will
need.
IMPORTANT: Do not use vent runs longer
than specified in the Vent Length Chart.
In the column listing the type of metal vent you
are using (rigid metal or flexible metal), find the
maximum length of metal vent on the same line
as the number of elbows.
B
4"
(10.2 cm)
2-1/2"
(6.4 cm)
Vent Length Chart
Number of 90°
Type of vent
turns or elbows
Rigid metal
0
Flexible metal
Rigid metal
1
Flexible metal
Rigid metal
2
Flexible metal

INSTALL VENT SYSTEM

1.
Install exhaust hood. Use caulking com-
pound to seal exterior wall opening around
exhaust hood.
2.
Connect vent to exhaust hood. Vent must
fit inside exhaust hood. Secure vent to
exhaust hood with 4" (10.2 cm) clamp.
3.
Run vent to dryer location. Use the
straightest path possible (see "Determine
Vent Length"). Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape,
screws or other fastening devices that
extend into the interior of the vent to se-
cure vent.

LEVEL DRYER

Check the levelness of the dryer. Check level-
ness first side to side, then front to back.
If the dryer is not level, prop up the dryer using
a wood block. Use a wrench to adjust the legs
up or down, and check the level again.
NOTE: It might be necessary to level the dryer
again after it has been moved into its final
position.
2-12
Box or louvered
Angled hoods
hoods
90 ft (27.4 m)
80 ft (24.4 m)
64 ft (19.5 m)
58 ft (17.7 m)
80 ft (24.4 m)
70 ft (21.3 m)
58 ft (17.7 m)
52 ft (15.8 m)
70 ft (21.3 m)
60 ft (18.3 m)
50 ft (15.2 m)
42 ft (12.8 m)