ELECTRICAL CONNECTION

Power Supply Cord
WARNING
Fire Hazard
Use a new UL listed 30 amp power
supply cord.
Use a UL listed strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal (silver).
Ground wire (green or bare wire) must
be connected to green ground
connector.
Connect remaining 2 supply wires to
remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to do so can result in death, fire,
or electrical shock.
1.
Disconnect power.
2.
Remove the terminal block cover.
A
B
A. Terminal block cover
B. Strain relief
C. Center, terminal block screw
D. External ground conductor screw
Direct Wire
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal (silver).
Ground wire (green or bare wire) must
be connected to green ground
connector.
Connect remaining 2 supply wires to
remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to do so can result in death, fire,
or electrical shock.
3.
4.
5.
C
D
2-5
WARNING
Fire Hazard
Unscrew the strain relief from the terminal
block cover.
Unscrew the strain relief nut from the
strain relief.
Put the power supply cord through the
strain relief nut, then the strain relief.
C
B
A
A. Power cord
B. Strain relief nut
C. UL listed Strain relief