Check Current Operational Mode; Disable Dcb; Configure Out Of Band (Oob) Management Port; Configure Login Credentials - Dell PowerConnect 8024 Configuration Manual

For equallogic sans
Hide thumbs Also See for PowerConnect 8024:
Table of Contents

Advertisement

3.5

Check current operational mode

Note: Before proceeding, the "System Operational Mode" must be set to "Normal". Some switches, such
as the M8024k, ship from the factory in simple mode.
console>enable
console#configure
console(config)#no mode simple
Switching modes will immediately clear the configuration.
to continue? (y/n) y
Switch has unsaved changes.
Are you sure you want to continue? (y/n) y
Note: The switch will reboot. If the switch reports "Normal mode already active", then you may proceed
to the next step without rebooting.
3.6

Disable DCB

Note: The PowerConnect M8024-k switches do not support Enhanced Transmission Selection (ETS),
therefore Data Center Bridging (DCB) must be manually disabled using the following steps. If you have
the M8024 switch, skip this section.
console>enable
console#configure
console(config)#no dcb enable
3.7

Configure out of band (OOB) management port

console(config)#interface out-of-band
console(config-if)#ip address ipaddress mask gateway
console(config-if)#exit
3.8

Configure login credentials

console(config)#line telnet
console(config-telnet)#login authentication default
console(config-telnet)#exit
12
SCG1008
PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs