S4810-On System Information; Boot Processes; Post; Eda, Quick Test Mode - Dell S6000–ON Troubleshooting Manual

Enterprise switches
Hide thumbs Also See for S6000–ON:
Table of Contents

Advertisement

Troubleshooting tools

S4810-ON system information

To view your system information; for example, the model, part number, serial number, and service tag, follow these steps.
1
Reboot your system and enter U-Boot mode.
2
Enter the sys_eeprom command.
Example of the sys_eeprom Command
dell_s4810_on-> sys_eeprom
TlvInfo Header:
Id String:
TlvInfo
Version:
1
Total Length: 73
TLV Name
-------------------- ---- --- -----
MAC Addresses
Base MAC Address
Vendor Name
Product Name
Part Number
Serial Number
Manufacturer
Service Tag
Label Revision
CRC-32
Checksum is valid.

Boot processes

After the BIOS or U-Boot hardware verifications, POST tests run to verify the CPU and memory prior to booting the system software.
After POST testing, there are three additional types of diagnostic tools you can use for testing your system.
Manual diagnostic boot process — To run additional testing, manually download and run the EDA tool. The EDA tool reports and logs
pass/fail results.
ONIE with EDA — EDA is installed; you do not have to manually download the tool. Select the diagnostic option at boot-up. You can
run this tool without a management interface.
Autorun EDA — EDA is installed; you do not have to manually download the tool. Select the diagnostic option at boot-up. You can run
this tool without a management interface. The system always launches EDA in Quick Test mode to verify the hardware components
before loading the software. If there is a failure at boot-up, based on the EDA configuration, the software may or may not continue the
boot process.

POST

POST diagnostics verifies system memory before the software loads. Test configuration parameters are saved in CMOS for the next boot-
up.

EDA, Quick Test Mode

Quick Test mode runs basic device access tests for the system hardware to verify that the device is active and responding.
In Quick Test mode, the EDA tool quickly tests if the hardware components are accessible. It confirms that the components respond to
read access and in some cases, simple write access. Tests are read-only and non-destructive (except the memtool command, which does
allow read/write operations).
Code Len Value
0x2A
2 65
0x24
6 00:E0:0C:02:01:FD
0x2D
4 Dell
0x21
8 S4810-ON
0x22
10 7590009602
0x23
13 HADL127B20077
0x2B
1 1
0x2F
2 123A1B2
0x27
3 A00
0xFE
4 0x4AF6A929
ONIE diagnostics