SPECIFICATIONS

BTU/h
Cooling Capacity
Power Supply
Dimensions
(WxDxH)
Weight
Evaporator Air Flow
Power Consumption
Current Consumption
Nema Plug
Refrigerant
Air Filter
Safety Devices
Power Cable
DEVICE
Length
Operating Range
High Pressure kgf/cm
Low Pressure kgf/cm
Max. Duct Length
Cold Duct
(Either hot or cold,
not both together
in use)
Hot Duct
Fuse in power box
in Machine body
14
H H S S C C - - 1 1 4 4
13,600
kW
(3.98)
inch.
19.3 X 23.6 X 46.8
lb
176
ft
3
/m
440
kW
1.5
Amp.
13
5-15
lb
R410A, 1.33
High Pressure Switch
Low Pressure Switch
Auto 'Full Tank'shut off.
Thermostat and relief valve for compressor
2
/psig
31/455.7
2
/psig
13/191.1
H H S S C C - - 1 1 8 8
16,800
(4.92)
115Va.c. 60Hz. 1Ph.
19.3 X 23.6 X 49.8
185
460
1.95
17
5-20
R410A, 1.76
Aluminium Mesh Cartridge
Fan motor protection
Tank position indicator.
3 min. delay timer.
Plug
9.8 ft.
72℉ DB 60% RH ~ 105℉ DB 40%
30 ft.
32.8 ft.
250Va.c. 10amp.
H H S S C C - - 2 2 4 4
H H S S C C - - 2 2 4 4 A A
23,500
23,500
(6.89)
(6.89)
220Va.c. 60Hz. 1Ph.
19.3 X 23.6 X 51.3
210
210
460
460
2.25
2.6
19.5
12
5-20
6-20
R22, 1.76
R22, 2.97
26/370
13/185
250Va.c. 5amp.