MENDOTA BLOWER & BURNER REMOVAL & INSTALLATION
BLOWER
ASSEMBLY
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after servicing.
The Mendota DXV Fireplace is designed so the blower operates at all times the fireplace is operating. The blower output can
be regulated with the rheostat (included), but it must be "on" at all times the burner is "on". NOTE: There will be a time
delay in blower operation during "heat-up" (approx. ½ hour) and extended blower operation during "cool-down" of unit.
(approx. ½ hour) NOTE: Power supply to blower must be continuous. DO NOT use switch or variable control in power
supplied to fireplace.

BLOWER WIRING

THERMO
DISK
MAIN BURNER
ORIFICE

BLOWER WIRING DIAGRAM

BLOWER OPERATION
2
7
BURNER
WELDMENT
REMOVABLE
BURNER PAN
VALVE
ASSEMBLY