Mendota DXV-42 Installation & Operating Instructions Manual page 39

Gas direct vent fireplace with hearthglo sealed combustion system
Table of Contents

Advertisement

MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM
As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is im-
portant
as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the
owner
for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with Warranty Regis-
tration
to Mendota. Optionally, please register at our website at: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP
HOME OWNER: ________________________________
ADDRESS: _____________________________________
CITY/STATE/ZIP: _______________________________
SIGNATURE: ___________________________________
MODEL #: DXV-42
Mendota direct vent fireplaces are sophisticated, hi-tech gas appliances. All installation and operating instructions must be care-
fully followed. The DXV fireplace must be installed and serviced by a qualified Mendota approved service person.
REF:
MENDOTA DXV INSTALLATION MANUAL
APPROVED VENT PIPES AND VENT CAP INSTALLED - Per Manual.
Vent pipes must be fully twist-locked and leak proof.
CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES - Per Manual
INSTALL PROPER SIZE GAS LINES - CHECK FOR GAS LEAKS - Per Manual
CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD - Per Manual
a.
3.5 Inches Water Column Maximum - Nat. Gas
b.
10.5 Inches Water Column Maximum - L.P. Gas
TAKE COMBUSTION SYSTEM MILLIVOLT READINGS [ Per Manual ]
a.
Pilot only - [Minimum Millivolts 460]
b.
Main burner operating - [Minimum Millivolts 100]
CYCLE BURNERS ON/OFF FOR PROMPT IGNITION - Per "LIGHTING INSTRUCTIONS"
Burner must light IMMEDIATELY - Flame must travel promptly around "curve" & light burner.
INSTALL LOGS AND ADJUST FLAME - Per Manual
Proper pilot flame impingement on thermopile & burner - Air shutter opening: 1/8" - 1/4" Nat. Gas - 1/2" LP
Check that flame is "stable" and is not "lifting" off burner
BRIEF OWNER ON OPERATION AND MAINTENANCE OF UNIT
Light Pilot
Your Name _______________________________________________________________________
Address __________________________________________________________________________
City ________________________________________ State ______ Zip ______________________
Dealer (Place of Purchase) ___________________________________________________________
City ________________________________________ State ______ Zip ______________________
Date of Purchase _______________________ Serial Number _______________________________
Purchaser's Signature________________________________________________________________
MENDOTA DXV-42 DIRECT VENT FIREPLACE
CUT OUT PAGE AND MAIL TO: JOHNSON GAS APPLIANCE CO., 520 E AVE. N.W. , CEDAR RAPIDS, IOWA 52405
Optionally, please register at our website at: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP
SERIAL #: ___________
Operate Burner
WARRANTY REGISTRATION
DEALER: ________________________________
ADDRESS: _______________________________
CITY/STATE/ZIP: _________________________
PHONE: _________________________________
DATE INSTALLED: ________________________
Reading: _______________________
Reading: _______________________
Explain blower "delay" operation
3
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents