Mendota DXV-42 Installation & Operating Instructions Manual page 33

Gas direct vent fireplace with hearthglo sealed combustion system
Table of Contents

Advertisement

NATURAL TO LP GAS CONVERSION
This conversion must be made by a qualified service technician.
1. Install main burner orifice #HA-11-00416 (#49 drill) see pg. 28 for location.
Orifice is removed and installed with a ½" deep well socket and ratchet.
2. Install pilot orifice #05-04-00036 (.014") see pg. 31 for location. Remove and install
pilot hood with 7/16" open end wrench. (pilot orifice thimble is located inside pilot hood
base)
3. Change L.P. screw (plug) #05-02-00294 as shown below.
HA-20-00141
3
2

Hide quick links: