Setting the Laser...
W
A X M I N S T E R
Aligning the Laser (Continued)
W H I T E
Check that the laser line is a fine line, not dispersed or splayed. Adjust this by loosening the
screw of the holder slightly, and twist the laser to give a fine straight line;(See Fig 16)
retighten the holding screw. Loosen the two caphead bolts that secure the mounting
bracket to the frame. (See Fig 17) Move the fitting until the laser is lined up, (this can
involve a small amount of twisting) almost lined up etc. Tighten the bolts very lightly and
check again. Unfortunately, even a very small movement will move the laser line
appreciably. Tightening the bolts must be done with care and may require several attempts
to get 'right' correctly. When all is correct remove the board and any tools you have used
during the setting up procedure, reconnect the saw to the mains supply.
To adjust the laser loosen the
!
Changing the Batteries
The unit is powered by 2 AAA cells fitted in the battery pack. To fit or change the batteries,
undo the three screws securing the lid, (See Fig 18) remove the lid, fit batteries as
required, (remembering to check the orientation of the batteries is correct); (See Figs
19,20) refit the lid to the battery pack.
Fig 18
20
Fig 16
screw on the holder
DISCONNECT THE SAW FROM THE MAINS SUPPLY
www.axminster.co.uk
To adjust the mounting bracket
loosen the two capheaded bolts
Fig 19
Fig 17
Fig 20

Advertisement