Check After Installation And Test Operation; Air Purging And Leakage Test; Outdoor Condensate Drainage - Toyotomi TAG-A16 HDI Service Manual

Table of Contents

Advertisement

Items to be checked
Has the unit been fixed firmly?
Have you done the refrigerant leakage test?
Is thermal insulation sufficient?
Is water drainage satisfactory?
Is the voltage in accordance with the rated
voltage marked on the nameplate?
Is the electric wiring or piping
connection installed correctly and securely?
Has the unit been securely earthed?
Is the power cord specified?
Is the inlet or outlet blocked?
Is the length of connection pipes
and refrigerant capacity recorded?
Possible malfunction
The unit may drop, shake or emit noise.
It may cause insufficient cooling(heating)
It may cause condensation.
It may cause water leakage.
It may cause electric malfunction
or damage the unit.
It may cause electric malfunction
or damage the parts.
It may cause electrical leakage.
It may cause electric malfunction
or damage the parts.
It may cause insufficient cooling(heating)
The refrigerant capacity is not accurate.
Manifold Valve
Multimeter
-76cmHg
Lo Handle
Low pressure valve
Fig.6
Vacuum pump
Drain-water hole
Bottom frame
Drain plug
Drain connecter
Hose (available commercially,
inner dia. 16mm)
Manometer
Hi handle
Charging hose