Vertical Swing; Big Horizontal Louver; Horizontal Swing - Toyotomi TAG-A16 HDI Service Manual

Table of Contents

Advertisement

Tpreset +3
Tpreset
Tpreset -2
Fan speed

3.8 Vertical Swing

3.8.1 Small Horizontal Louver
After energization, vertical swing motor will firstly have the horizontal louver rotate anticlockwise to position O to close air outlet. If
swing function has not been set after startup of the unit, horizontal louver will turn clockwise to position D1 in HEAT mode. If swing
function is set when starting up the unit, the horizontal louver will swing between O and D1.There are 7 swing status of horizontal
louver: Positions O, A1, B1, C1 and D1, swing between O and D1 and stop at any position between L and D (angles between O and
D1 are equiangular). Upon turning off the unit, the horizontal louver will close at position O. Swing function is available only when
swing function is set and indoor fan is operating.
Note:
a. If the position is set between O and D1, A 1and C1 or B1 and D1 by remote controller, the horizontal louver will swing between O
and D1.
b. For model 9K/12K, only when big horizontal louver rotates to the second position for heating( 62°of corresponding angle), this louver
will be activated; For 18K model, only when big horizontal louver rotates to the first position for heating(64°of corresponding angle),
this louver will be activated; For 24K mode, only when big horizontal louver rotates to the first position for heating(40°of corresponding
angle), this louver will be activated.
c. Under cooling mode, this horizontal louver will be always in the position O.

3.8.2 Big Horizontal Louver

After energization, up & down swing motor will firstly have the horizontal louver rotate anticlockwise to position O to close air outlet. If
swing function has not been set after startup of the unit, horizontal louver will turn clockwise to position D in HEAT mode, or turn
clockwise to level position L in other modes. If swing function is set when starting up the unit, the horizontal louver will swing between L
and D.There are 7 swing status of horizontal louver: Positions L, A, B, C and D, swing between L and D and stop at any position
between L and D (angles between L and D are equiangular). Upon turning off the unit, the horizontal louver will close at position O.
Note: If the position is set between L and B, A and C or B and D by remote controller, the horizontal louver will swing between L and D.

3.9 Horizontal Swing

Upon energization, the vertical louver will be reset to the start position firstly and then stop in the middle position. When setting
Tamb.
High
Med.
Low
(0 degree)
Mute
(0 degree)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents