Service water enters the filter and passes through air
captured at the top of the mineral tank. Dissolved
iron, manganese and sulphur are oxidized and then
removed by the media in the tank. When the system
recharges, it first backwashes the contaminants to the
Care is taken at the factory to keep your water filter
clean and sanitary. Materials used to make the filter
will not infect or contaminate your water supply, and
will not cause bacteria to form or grow. However,
during shipping, storage, installing and operating,
bacteria could get into the filter or media. For this
reason, sanitizing as follows is suggested* when
installing.
1. Obtain pharmaceutical grade 12% hydrogen perox-
ide solution. One quart (0.95 L) is required for a
10" filter, 2 quarts (1.9 L) for a 12" filter.
2. Remove air inlet screen from check valve on the
valve's nozzle & venturi assembly (See Figure 10).
3. Connect a length of 3/8 I.D. tubing to the barb on
the aspirator check valve (See Figure 11).
4. Insert the free end of the tubing into the hydrogen
peroxide container.
5. Push and hold the RECHARGE button until the fil-
ter starts a RECHARGE NOW cycle. The filter will
backwash for 15-17 minutes, then advance auto-
matically to the "aspirate" position. It will draw the
hydrogen peroxide into the filter and pass it
through the zeolite media, cleaning and sanitizing
the media.
6. Allow the filter to draw air for the remainder of the
time in the "aspirate" cycle after the hydrogen per-
oxide has been drawn into the filter.
7. The filter will return to "service" automatically when
the "aspirate" cycle is complete.
8. Remove tubing and reinstall the aspirator inlet
screen onto the barbed fitting on aspirator check
valve.
9. Cleaning/sanitizing process is complete.
*NOTE:
Sanitizing is recommended by the Water Quality
Association for disinfecting. On some water sup-
plies, they suggest periodic sanitizing.
Description of Operation & Sanitizing
DESCRIPTION OF OPERATION
drain, then empties the tank of water, replacing it with
air drawn through the aspirator. When the system
returns to "service", the water pressure will compress
the air in the mineral tank and leave an 8-14" head of
air on the top of the tank.

SANITIZING PROCEDURE

9
Valve nozzle &
venturi assembly
Check valve
3/8" barb
Remove air
inlet screen
Valve nozzle &
venturi assembly
Check valve
3/8" barb
Connect 3/8" I.D.
tubing to barb
Place other end of tube in
hydrogen peroxide solution
FIG. 10
FIG. 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Etf aiv-12Etf eiv-10

Table of Contents