Dell PowerEdge C6220 II Owner's Manual page 260

Hide thumbs Also See for PowerEdge C6220 II:
Table of Contents

Advertisement

CAUTION: If removed, you must replace the power distribution board 2 and the
power distribution board-connector before replacing the power distribution board
1.
1
If removed, first place the power distribution board 2 in the system.
See Figure 3-77. Otherwise skip to step 5.
NOTE: To install the power distribution board 2 below the power distribution board
1, angle the board during installation.
2
Replace the screws securing the power distribution board 2 to the
system. See Figure 3-77.
3
Replace the power distribution board-connector. See Figure 3-76.
4
Connect all the cables to the power distribution board 2. See Figure 3-
79.
You must route these cables properly through the tabs on the chassis to
prevent them from being pinched or crimped.
5
Replace the power distribution board 1 to the system. See Figure 3-75.
6
Replace the screws securing the power distribution board 1 to the
system. See Figure 3-75.
7
Connect all the cables to the power distribution board 1. See Figure 3-
78.
You must route these cables properly through the tabs on the chassis to
prevent them from being pinched or crimped.
8
Replace the power supply. See "Installing a Power Supply" on page 167.
9
Close the system. See "Closing the System" on page 152.
10 Reconnect the system to its electrical outlet and turn on the system,
including any attached peripherals.
260
|
Removing and Installing System Components