Cpu Card - IBM 7012 300 Series Installation And Service Manual

Table of Contents

Advertisement

CPU Card

Note: Refer to "Handling Static-Sensitive Devices" on page 3-2 before removing or
Removal
1. Set the power switches of the attached devices to Off.
2. Set the power switch of the system unit to Off.
3. If the system unit has a rear cover, do the rear cover removal procedure on page 3-3.
4. Do the Top Cover removal procedure on page 3-4.
5. On Models 340 and 350, remove the CPU shield.
6. Make a note of its position and remove the CPU card.
Note: For specific system planar connector locations refer to pages1-5 and 1-6.
1
2
3
4
Figure 2. System Planar Connector locations illustration.
Replacement
Reminder to Service Representative: After you exchange the CPU card, notify the
customer that the unique identification number of the system unit has changed. The
customer needs to update the authorization number for any program that uses the
identification number for access.
1. Align the CPU card with the front and rear card guides and the connector, and then press
the CPU card down into the connector.
2. Replace the CPU shield on Models 340 and 350.
3. Do the Top Cover replacement procedure on page 3-4.
4. If the system unit has a rear cover, do the rear cover replacement procedure on page
3-3.
5. Set the power switches of the attached devices to On.
6. Set the power switch of the system unit to On.
3-30
Installation and Service Guide
installing the CPU card in this system. For Model 39H, refer to the "CPU Card for
Model 39H" removal procedure on page 3-31.
J16
J15
J14
J13
J12
J11
J10
J8
J9
J18
J6
J7
J5
J17
J1
J27
J2
J25
J24
A
J19
B
C
J20
J23
CPU Card
Connector
J22
J21