Note 1:
Collisions are not detected by the device operating in full-duplex mode: packets from this device are
never re-transmitted if a collision occurs on them.
The following table lists all possible Ethernet port configuration combinations when connecting
an IP Touch set to an external device (switch on LAN side, PC on PC side). For each combination,
the table shows the link status: valid or invalid (duplex or speed mismatch), as described above.
Terminal Port
1
auto-negotiation
2
auto-negotiation
3
auto-negotiation
4
auto-negotiation
5
auto-negotiation
6
100-FULL
7
100-FULL
8
100-FULL
9
100-FULL
10
100-HALF
11
100-HALF
12
100-HALF
13
10-FULL
14
10-FULL
15
10-HALF
Note 2:
To prevent slowness problem on PC when the two ports of an Alcatel-Lucent IP Touch 4008 EE/4018 EE or
Alcatel-Lucent IP Touch 4008 EE/4018 EE phone Extended Edition set are configured in auto-negotiation
mode, if the negotiation has led to a 10 Mbps rate on the PC port and a 100 Mbps rate on the LAN port,
the IP Touch set automatically tries to renegotiate a 10 Mbps rate on the LAN port.
All Rights Reserved © Alcatel-Lucent 2009
table 2.2: Ethernet Link Combinations
External Device Port
auto-negotiation
100-FULL
100-HALF
10-FULL
10-HALF
100-FULL
100-HALF
10-FULL
10-HALF
100-HALF
10-FULL
10-HALF
10-FULL
10-HALF
10-HALF
Link Status
Valid
Invalid (packet loss)
Valid
Invalid (packet loss)
Valid
Valid
Invalid (packet loss)
Invalid (no link)
Invalid (no link)
Valid
Invalid (no link)
Invalid (no link)
Valid
Invalid (packet loss)
Valid