Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet
(2m) of icemaker in accordance with local and national codes. Outdoor
installation is not recommended and will void warranty.
2.1
2.1
Installation site requirements
Electrical
• H_C700(A/W)HS 208-230/60/1-15 amp breaker • H_D700(A/W)HS 115/60/1-15 amp breaker
(H_C700A/W Requires a 15 amp dedicated circuit)
• H_E700(A/W)HS 230/50/1-15 amp
(H_E700A/W Requires 15 amp circuit 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Water supply must be treated by a scale-inhibiting fi lter (item# 00130286)
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 20 to 90 F (-7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
• The drain line from the ice machine must be vented and have at least 1/4" per foot
(6,4mm/0,3m) pitch
HARMONY • RIDE Technology
1/4"
1'
breaker
2
wire)
self-contained
115V ±5%
208V -5% to 230V +5%
(H_D700A/W Requires a 15 amp dedicated circuit)

Site preparation

H_D700A/W
NEMA
6-15
H_D700A/W
NEMA
5-15
2
5