6-6
Maintenance
Figure 6-7
Control Panel Aperture
Part 7119745C
Disconnect the conveyor motor supply cable by unplugging the orange
connector, reach in through the control panel aperture.
1
1. Fuses
Remove the 4 x M8 hexagon key bolts that secure the conveyor top in
place.
With assistance, the complete conveyor assembly can now be removed
from the lower cabinet to reveal the electrical components.
When replacing the conveyor, extra assistance may be required to feed the
lamp supply cables back through the grommets. Also, ensure that the fan
duct locates correctly into the fan before replacing the M8 bolts.
MiniCure 08-07
2
FIG. NUV8A
2. Motor Connector
(Orange Color)
E 2007 Nordson Corporation