Nordstrom MiniCuret 7119745C Product Manual page 32

Table of Contents

Advertisement

4-2
Installation
The air outlet port should be connected to 100mm diameter extraction
ducting that must vent to atmosphere. This must be a maximum of 2
metres long. Larger diameter extraction tubing, and external balanced fan
assistance are required if you have to make a longer run than 2m. It is
advisable that this is not vented into any air--conditioning ducting or any
existing extraction system without extreme caution. Please contact
Nordson UV for advice if required.
NOTE: The air temperature flowing through this ducting can reach up to 80
degrees Centigrade, so adequate physical protection must be provided to
ensure that accidental contact is avoided.
Fit the substrate collection tray to the outlet shield.
NOTE: The subtrate collection tray on the outfeed of the unit forms part of
the UV shielding. If this tray is not fitted alternative shielding methods must
be provided for operator and bystander safety.
MiniCure 08-07
Part 7119745C
E 2007 Nordson Corporation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Minicure 7119745c

Table of Contents