High Voltage Connections; Lamphead Cleaning; High Temperatures - Nordstrom MiniCuret 7119745C Product Manual

Table of Contents

Advertisement

1-10
Safety

High Voltage Connections

Careful checks should be kept on the lamp connections and high voltage
connections within the equipment to make sure that these do not become
dirty or coated with powder or other possible conducting material. They
should be cleaned regularly, at least whenever the lamp is changed,
possibly more often where a particularly heavily polluted atmosphere
occurs. Also, while changing the lamps, a careful check should be made of
the high voltage leads to make sure that no deterioration has occurred.
Dirty contacts may cause a potential hazard.

Lamphead Cleaning

The air inlets in the reflector head should be regularly checked, so that it is
ensured that they have not become blocked with dust or powder and that
the air passages are clear.

High Temperatures

It should be noted that the reflector head runs at very high temperatures
and the inside components become very hot during operation of the
machine and the equipment. Therefore, when maintaining the equipment, a
reasonable time should be allowed before access is attempted.
Alternatively, precautions should be taken.
MiniCure 08-07
Part 7119745C
E 2007 Nordson Corporation