Schwank S100 Installation & Owner's Manual page 25

Schwank low intensity tube type infrared heaters
Hide thumbs Also See for S100:
Table of Contents

Advertisement

FIGURE 19 REFLECTOR EXTENSIONS
Reflector extensions
may be installed one
or both sides
1. Reflector extensions may be installed on
one side or both sides of the reflector
2. Reflector extensions are 116" (295 cm)
long
3. Holes (3) in the reflector extension for "S"
hooks are located 2.25" (5.7 cm) from
each end and one at the center
4. Drill 1/4" (7 mm) holes in the reflector
3/4" (2 cm) up from the bottom edge of
the reflector to align with the 3 holes in
the top of the reflector extension
5. Insert "S" hook down through hole in the top of the reflector extension
6. Rotate "S" hook approx. 90°, and insert into hole drilled in reflector
7. Settle reflector extension into place
Insert 'S' hook
from top and
rotate
5
6
(OPTIONAL - IF REQUIRED )
Reflector Extension Kit JS-0509-KT
Includes:
 Qty 1 x 10 ft long x 10 inch deep reflector
extension
 Qty 3 x "S" Hooks
7
25
S100-F / ITB-F I&O Manual
IM101230
RD: JAN 2014
RL: 9A