Schwank S100 Installation & Owner's Manual page 19

Schwank low intensity tube type infrared heaters
Hide thumbs Also See for S100:
Table of Contents

Advertisement

FIGURE 11 'U'-TUBE TYPICAL HANGER & SUPPORT SPACING
SUSPEND FIRST TUBES BY TWO (2) HANGERS, THEN SUBSEQUENT SECTIONS BY ONE HANGER
LOCATE HANGERTS BETWEEN 6" to 18" FROM EACH TUBE COUPLER.
INSTALL FIRST AND SECOND TUBES (FROM BURNER END) WITH WELDED SEAM FACING DOWNWARD.
1 - END CAP
2 - WIRE HANGER
3 - BURNER ASSEMBLY
4 - COMBUSTION AIR OPTIONS:
4A - JS-0532-SE 4" INTAKE
ADAPTER
FIGURE 12 'U' TUBE MODELS
'U' TUBE HANGER
FIGURE 12A
FIGURE 13 'U' TUBE MODEL ORIENTATION
4B - JS-0532-VC 4" WALL CAP
4C - JA-0528-XX 4" ROOF CAP
5 - SIGHT GLASS
6 - ALUMINIZED TUBE WITH
FLANGE
7 - TORCTITE TUBE COUPLER
19
8 - STEEL TUBE(S)
9 - REFLECTOR
10 - FLUE VENT TERMINAL
11 - BURNER SUPPORT CHAIN
12 - HANGER SUPPORT
CHAINS
TURN BOX
FIGURE 12B
S100-F / ITB-F I&O Manual
RD: JAN 2014
IM101230
RL: 9A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

ItbItbuS100u

Table of Contents