Connecting The Screen; Re-Circulating Requirements - Sirius Range Hoods SU1 Installation Instructions Manual

Wall range hoods
Table of Contents

Advertisement

Available languages

Available languages

fig. 11
Connecting the Screen (SU 202 Only).
Before attaching the screen the power
unit wipe the face of the flange to en-
sure there is no grit present – if there is
this will most definitely crack the glass.
The plastic washers must be positioned
between the screw head and the glass. Fit
the screen – please have some-one hold
this in place whilst another person puts in
the screws. Using FINGERS ONLY, tighten
the screws evenly until finger tight. Do
not under any circumstances use a screw
driver.

Re-Circulating Requirements.

If the unit is to be used in the re-cir-
culating mode, fit the carbon filter af-
ter the installation is complete (refer to
Figure 12) fit the deflector (refer Figure
13) with the screws supplied to the up-
per telescope chimney. There are holes
in the back upper edge of the decora-
tive chimney for this purpose. A short
length of ducting is connected between
the exhaust outlet on the fan and the
deflector to direct the air back into the
kitchen through the vents at the top of
the upper decorative chimney.
10
The carbon filter (supplied separately)
that absorbs odors is installed behind
the aluminium grease filter (refer to Fig
14).
fig. 12
fig. 13
fig. 14