MINIMUM CLEARANCES TO COMBUSTIBLES

Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is
used, do not block the lower control compartment door. Any hearth extension used is for appearance
only and does not have to conform to standard hearth extension installation requirements.
Wall Finishes / Surrounds / Mantels
Note: Combustible wall fi nish materials and/or surround materials must not be allowed to encroach
the area defi ned by the appliance front face (black sheet metal). Never allow combustible materials
to be positioned in front of or overlapping the appliance front face. See Figure 56 on Page 31.
Non-combustible materials, such as surrounds and other appliance trim, may be installed on the
appliance front face with these exceptions: they must not cover any portion of the removable glass
panel or louvers.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel.
See Figure 7. Mantels constructed of non-combustible materials may be installed at any height
above the appliance opening; however, do not allow anything to hang below the hood.
Mantel Depth
14 (356)
12 (305)
10 (254)
8 (203)
6 (152)
4 (102)
12
10
(305)
(254)
(203)
Figure 7 -
Minimum Mantel Clearances
Combustible Shelf Height - Inches (millimeters)
Model No.
Top Vent - with One 90 Degree Elbow
Secure Vent
SDDV-35
*53-1/2 (1359)
SDDV-40
* Includes 3" clearance to combustibles (required above vent components)
Do not insulate the
space between the
appliance and the
area above it.
Shelf Height
(
see table)
Shelf Above Fireplace With Rear Venting
Figure 8 -
Shelf Height Minimum Clearances
Top of
Appliance
8
6
4
2
(152)
(102)
(51)
Hood
Rear Vent - Straight Out the Back
Secure Flex
Secure Vent
(fl ex elbow)
*55-1/4 (1403)
40-1/4 (1022)
Do not insulate the
space between the
appliance and the
area above it.
*Shelf Height
(
see table)
Shelf Above Fireplace With Top Venting
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
inches (millimeters)
Minimum Distance to Unprotected Side Wall
Combustible materials may project beyond the sides of the fi re-
place opening as long as they are kept within the shaded areas
Secure Flex
illustrated here.
At 14" minimum
40-1/4 (1022)
side wall clearance,
a combustible wall
can project to any
length.
14
(356)
Appliance and Vent Clearances
The appliance is approved with zero clearance to
combustible materials on all sides (as detailed
in Table 8), with the following exception: When
the unit is installed with one side fl ush with a
wall, the wall on the other side of the unit must
not extend beyond the front edge of the unit.
In addition, when the unit is recessed, the side
walls surrounding the unit must not extend
beyond the front edge of the unit. See Figure
3 on Page 6.
MINIMUM CLEARANCES
Inches (millimeters)
Back
1/2 (13)
0 (0) Spacers
Sides
1/2 (13)
0 (0) Spacers
Top Spacers
Floor
Bottom of Appliance
64 (1626)
To Ceiling
Vent
3 (76)
1 (25.4)
SERVICE CLEARANCES
Feet (meters)
Front
3 ft. (0.9 m)
Table 8
*Note: 3 in. (75 mm) above any horizontal/in-
clined vent component.
**Note: See Page 10, Step 1 for clearance
requirements to the nailing fl ange located
at each side of the unit and any screw heads
adjacent to it.
At 8-1/4" side
wall clearance, a
Top View of
combustible wall
Fireplace
can project 12"
Combustible Materials
45 o
Allowed In Shaded
5
(127)
Area "Safe Zone"
Combustible Walls
shown in dark gray
12
(305)
17
(432)
Inches (millimeters)
8-1/4
Protected wall shown in white
(209)
0 (0)
0 (0)
*
Top
Sides & Bottom
Figure 9
9