Power S upply Cord
Direct W ire
FireHazard
Usea newULapproved 30amppower
supplycord.
Usea ULapproved strain relief.
Disconnect p owerbeforemakingelectrical
connections=
Connect n eutralwire(whiteor centerwire)to
centerterminal(silver).
Groundwire(greenor barewire)mustbe
connectedto greengroundconnector.
Connect r emaining2 supplywiresto remaining
2 terminals(gold).
Securely tightenallelectricalconnections.
Failure to do so can resultin death,fire,or
electricalshock.
FireHazard
Use10gaugesolid copperwire.
Usea ULapproved strain relief.
Disconnect p owerbeforemakingelectrical
connections=
Connect n eutralwire(whiteor centerwire)to
centerterminal(silver).
Groundwire(greenor barewire)mustbe
connectedto greengroundconnector.
Connect r emaining2 supplywiresto remaining
2 terminals(gold).
Securely tightenallelectricalconnections.
Failure to do so can resultin death,fire,or
electricalshock.
1. Disconnect power.
2.
Remove the hold-down
screw and terminal block cover.
2
4
3.
Assemble a 3/4in. (1.9 cm) UL approved strain relief (UL
marking on strain relief) into the hole below the terminal block
opening. Tighten strain relief screws just enough to hold the
two clamp sections together. Put power supply cord through
the strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position.
4.
Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
1. Terminal block cover and hold down screw
2. External ground connector
3. Neutral grounding
wire (green/yellow)
4. Center, silver-colored
terminal-block
screw
8