Kenmore 8519319A Use & Care Manual page 9

He3
Table of Contents

Advertisement

Available languages

Available languages

Electrical Connection Options
If your home has:
And you will be
Go to Section
connecting to:
4-wire receptacle
A UL listed,
4-wire connection:
(NEMA Type 14-30R)
120/240 volt
Power supply cord
minimum, 30
amp, dryer
power supply
cord*
4-wire direct
A fused
4-wire connection:
disconnect
or
Direct Wire
circuit breaker
box*
3-wire receptacle
A UL listed,
(NEMA type 10-30R)
120/240 volt
minimum, 30
amp., dryer
power supply
cord*
3-wire connection:
Power supply cord
3-wire direct
A fused
3-wire connection:
disconnect
or
Direct Wire
circuit breaker
_"
_
box*
*If local codes do not permit the connection of a frame-grounding
conductor to the neutral wire, go to "Optional 3-wire
Connection"
section.
4-wire conneclion:
Power supply cord
IMPORTANT:
A 4-wire
connection
is required
for mobile
homes
and where
local codes
de not permit
the use of 3-wire
connections.
2
6
5
7
1.4-wire receptacle
(NEMA type 14-30R)
2. 4-prong plug
3. Ground prong
4. Neutral prong
5. Spade terminals with upturned
ends
6. z/4in. (l.g cm) UL approved
strain relief
7. Ring terminals
1. Remove center terminal block screw.
2.
Remove appliance ground wire (green with yellow stripes)
from external ground connector screw. Fasten it under center,
silver colored terminal block screw.
3
1. External ground connector - Dotted line shows
position of NEUTRAL ground wire before being
moved to center terminal block screw
2. Center silver-colored
terminal block screw
3. Green/yellow
wire of harness
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor
screw. Tighten screw.
4. Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block.
2
3
1. External ground connector
2. Green or bare copper wire of power supply cord
3. ¾ in. (1,9 cm) UL-tisted strain relief
4. Center silver-colored
terminal block screw
5. Neutral grounding
wire (green/yellow)
6. Neutral wire (white or center wire)
5. Connect the other wires to outer terminal block screws.
Tighten screws.
6. Tighten strain relief screws.
7.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down
screw.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

110. series

Table of Contents