  • Page 1 SCENA COMPACT LED 50 User’s Manual rel. 1.0 GB D.T.S. Illuminazione s.r.l. – ITALY http://www.dts-lighting.it/ Made in Italy...
  • Page 2 Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso scritto della D.T.S . D.T.S.
  • Page 3: Table Of Contents

    INDEX: 1- SYMBOLS 2- GENERAL WARNING 3- GENERAL WARRANTY CONDITION 4- TECHNICAL FEATURES 5- ACCESSORIES 6- IMPORTANT SAFETY INFORMATION 6.1 Fire prevention 6.2 Prevention of electric shock 6.3 Safety 7- INPUT / OUTPUT CONNECTIONS 8- DMX SIGNAL CONNECTION 8.1 DMX Addresses 8.2 Selecting the DMX address 9- FIRMWARE UPDATING 10- DISPLAY FUNCTIONS...
  • Page 4: 1- Symbols

    1- SYMBOLS Graphic symbols used on this manual: THIS SYMBOL INDICATES A HOT SURFACE THIS SYMBOL INDICATES ELECTRIC SHOCK RISK THIS SYMBOL INDICATES GENERAL RISK THIS SYMBOL MEANS YOU CAN PLACE THE UNIT ON NORMALLY FLAMMABLE SURFACES THIS SYMBOL INDICATES THE MINIMUM LED 30 cm DISTANCE TO BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT...
  • Page 5: 4- Technical Features

    LED, and a wide excursion zoom, enabling it to be used as a Beam or a very wide Wash. SCENA COMPACT LED 50 is a modern alternative to conventional lights, improving light quality, flexibility of use and installation, energy savings and component duration.
  • Page 6: 5- Accessories

    DIMENSIONS 5- ACCESSORIES As standard 1 x User’s Manual 1 x POWERCON male cable connector (D.T.S. Code 0520P014) 1 x XLR 5 pins male cable connector (D.T.S. Code 0508B028) 1 x XLR 5 pins female cable connector (D.T.S. Code 0508B027) Optional (on request) - “C”...
  • Page 7: 6- Important Safety Information

    The use of a thermal magnetic circuit breaker is recommended for each SCENA COMPACT LED 50 unit. Use only AC supplies 90-260V , 50 / 60 Hz. SCENA COMPACT LED 50 should never be located in position exposed to rain or in areas of extreme humidity.
  • Page 8: 8- Dmx Signal Connection

    9- DMX SIGNAL CONNECTION: The unit operates using a digital DMX 512 signal. Connection between the controller and the unit or between units must be carried out using a two pair screened ø 0.5 mm. Ensure that the conductors do not touch each other. Do not connect the cable ground to the DMX connector chassis.
  • Page 9: Dmx Addresses

    DMX address. 10- FIRMWARE UPDATING To update the software version of the SCENA COMPACT LED 50 you need: - D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008) - USB-DMX Driver for the D.T.S. RED BOX interface - “D.T.S.
  • Page 10: 10- Display Functions

    10- DISPLAY FUNCTIONS DISPLAY FUNCTIONS The SCENA COMPACT LED 50 display panel shows all the available functions. Using these functions, it is possible to change some of the parameters and add some functions. Changing the D.T.S. setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it.
  • Page 11 (D.T.S. Code: 03.LA.016) ENTER INFRARED MODE Infrared remote control. By activating Ir Mode, it will be possible to navigate trought the unit NOT IMPLEMENTED ON SCENA COMPACT LED 50 functions by using the D.T.S. infrared remote control (D.T.S. Code: 0514L008)
  • Page 12 To log SCENA COMPACT LED 50 off from a transmitter simply select UNLINK function under WIRELESS DMX MENU and press ENTER. When SCENA COMPACT LED 50 is logged off, the display is blinking, meaning its available for log in on a new transmitter. Logging out a SCENA COMPACT LED 50 Select UNLINK function under WIRELESS DMX MENU and press ENTER.
  • Page 13 Default = OFF MENU Up-Down ENTER Up-Down ENTER ENTER Up-Down EMERGENCY Emergency operating mode. ENTER By setting Emergency mode, it will be possible to select Default = 204 (80%) Dimmer intensity level that will ENTER then ran if DMX signal is missing or not available.
  • Page 14: 11- Dmx Protocol

    11- DMX PROTOCOL 2 CHANNELS MODE (Default) SHUTTER / STROBE DIMMER DMX CHANNEL Parameter: SHUTTER / STROBE Function DMX range Mid Point Move Range Mode Option Value (degrees) value 000-009 Black-out 010-019 Open 020-029 Black-out 030-119 Strobe (from 3.27 s to 30 ms) 120-149 Pulse up (from 42.6 s to 120 ms) 150-179...
  • Page 15 3 CHANNELS MODE SHUTTER / STROBE DIMMER DIMMER FINE DMX CHANNEL Parameter: SHUTTER / STROBE Function DMX range Mid Point Move Range Mode Option Value (degrees) value 000-009 Black-out 010-019 Open 020-029 Black-out 030-119 Strobe (from 3.27 s to 30 ms) 120-149 Pulse up (from 42.6 s to 120 ms) 150-179...
  • Page 16 ISO 9001:2008 standard D.T.S. products are designed and manufactured at the D.T.S. plants in italy *0517I222* 0517I222 D.T.S. Illuminazione s.r.l. – Via Fagnano Selve 10-12-14 47843 Misano Adriatico (RN) Italia Tel.: +39 0541 611131. Fax + 39 0541 611111 info@dts-lighting.it www.dts-lighting.it...