5 -

INSTALLATION

C
D
A
B
fig. 2
A
MAINS SUPPLY
B
DISCHARGE DUCTS
C
PROTECTION SWITCH
D
PURI.IER
E
DRIP BOWL
.
POWER CABLE
Before proceeding with installation check that:
1 there are no bumps, signs of knocks or deformities.
2 there are no damp patches or marks which could lead one to
assume that the packaging has been exposed to the elements
3 there are no signs of tampering
Once one is satisfied that transportation has been correctly
effected proceed with installation.
Proceed with installation following the instructions according
to the sequence as described below.
N.B. The least height of the support's top must be 110cm.

5.1 Water connection

Important: The machine must be supplied with
water of over 8°. hardness.
The installation of a water softener is recommended for the
machine water supply.
E
Check that the water mains to which connection is to be
made supplies drinking water.
-
Connect purifier (D) to the water mains (A).
NB: before connecting the purifier to the machine,
wash out thoroughly until the water becomes clear,
then proceed to connect the purifier to the machine.
-
Connect the drain cup (E) to the drainage pipe (B)
F
-
Should the mains pressure be higher than 5 bar a pressure
reducer balanced for high pressure should be installed (device
in which any mains pressure increase does not effect the output
pressure).

5.2 Electrical connection

Important ! Before proceeding with electrical
connection it is necessary to check to ensure that the
voltage rating corresponds with that indicated on
the CE plate and on the connection plate on the
power supply cable.
Check to ensure that the electrical supply line is able to
support the machine load (see chap. 4 – technical features
table).
Connect to an earthing socket which complies with current
legislation.
Check that the power supply cable is efficient and that it
complies with national and European safety standards.
The user must undertake to power the machine protecting
the power line using a suitable safety switch (cut-out) that
complies with the legislation in force in the actual country
itself.
Connect the power cable (.) to the electric line using a
plug, or in the case of fixed installation, using a multi-polar
switch (C) for mains separation, with a contact distance of
at least 3 mm.
.or voltage change refer to the diagram shown on the general
mains switch box.
The yellow-green coloured cable MUST be connected to
the room’s earthing system.