Example of Toll Restriction programming
Here is an example to explain the procedures for Toll Restriction programming.
1.
Determining the application
Determine the dialling numbers that should be denied for levels 2 through 6. (Levels 1,
7 and 8 are fixed and do not require programming.)
Level
Note: "x" substitutes a digit.
Features Guide
[Entry Example]
Denied Code
2
011
3
011
976
1xxx976
4
011
976
1xxx976
0
5
011
976
1xxx976
0
411
1xxx555
6
011
976
1xxx976
0
411
1xxx555
1
x0
x1
Excepted Code
None
None
None
None
911
1911
130