External Connectors

Most external connectors for the VX3Plus are located on the top of the unit.
The RS-232 port, if present, (COM1 or COM3) connects to a serial barcode scanner, PC or printer.
l
The USB-C port, if present, provides a USB Client connection.
l
The USB-H port, if present, provides a USB Host connection.
l
Audio connects to a mono or stereo telephone headset/microphone.
l
An optional connector for a remote mount antenna.
l
When the remote antenna mount is ordered, the VX3Plus does not have an audio connector.
RS-232 Connector (COM1 or COM3)
When present, the serial connector, labeled "RS-232", (configured as COM1 or COM3 depending on endcap option selected) is
industry-standard RS-232. The connector includes a PC/AT standard 9–pin "D" male connector. By default, Pin 9 to provide RI.
Pin 9 of
COM1
or
COM 3
Power the VX3Plus off before attaching a cable or device to the COM1 or COM3 serial port.

Technical Specifications - Connection Cable

The exact serial cable is crucial. Many commercial null modem cables will not work. The following cable is recommended:
Serial Cable - 9000060CABLE
may also be configured to supply +5 VDC at 0.4A (max) for an external bar code scanner.
Pin
Signal
1
DCD
Data Carrier Detect - Input
2
RXD
Receive Data - Input
3
TXD
Transmit Data - Input
4
DTR
Data Terminal Ready - Input
5
GND
Signal/Power Ground
6
DSR
Data Set Ready - Input
7
RTS
Request to Send - Output
8
CTS
Clear to Send - Input
+5VDC Bar Code Scanner Power - 400mA max (default)
9
RI
Ring Indicator
Shell CGND Chassis Ground
Description
2-7