4. DETERMINING WATER FLOW

Plumbing.
The machine must be plumbed in as shown, see diagrams below (a tear off label is attached to the machine on
delivery).
Adjust the flow rate until the flow light is illuminated, giving the correct flow rate. The "adequate flow" symbol
looks like this:
SYMBOL CHART- ALL MACHINES
FLOW LAMP ILLUMINATED,
=I
ADEQUATE FLOW
FLOW LAMP NOT
=0
ILLUMINATED,
INADEQUATE FLOW
POOL/SPA
PUMP
FILTER
WATER HEATING AFTER
6 MINS
I=
6 MINUTE DELAY
REMOVE AND DISPOSE
OF LABEL
POOL
WATER IN
(REMOVE BUNG
BEFORE
INSTALLING
MACHINE)
MACHINE SIDE
AW631 AND AW831 FLOW RATE 115 LITRES PER MINUTE
AW1231 AND AW1531 FLOW RATE 160 LITRES PER MINUTE
6 MINS
I=
MACHINE LABEL
Page 10
=I
=0
POOL
WATER OUT
(REMOVE BUNGS
BEFORE INSTALLING
MACHINE)
CONDENSATE
DRAIN