3�2� POOL WATER CIRCUIT
Pool
Aux heater
Non return
Sanitiser or
(If fitted)
valve
chemical dosing
device,
(If fitted)
Calorex
Heat pump
Anti return loop
Condensate
to be incorporated,
water to
To waste
minimum height
waste
100mm above
heat pump
outlet port
(If sanitiser fitted)
To waste
Bypass
Spare port
Filter
Pump
for
valve
for winterising
winterising
(Normally
flushing
drain down
closed)
connection
KEY
Isolation valve
Breakable coupling
Three way valve