TC30.NG06C 200411-16
12. Replace the minimum rate screw with the
one provided in the propane conversion
kit supplied with this fi replace. Ensure
that the screw is fully installed.
(Fig. #24)
13. Remove the aluminum cap from the top
of the pressure regulator. (Fig. #25)
14. Press down on the center post and
rotate 90°. The center post should
stay down. (Fig. #26). Replace the
aluminum cap.
15. Fill in the date and the name of the
person who performed the conversion in
the white area on the conversion label.
Peel off the protective backing and apply
the conversion label directly over the
gas specifi cations on the rating label.
16. Attach the access panel to the side of
the fi rebox with the previously removed
screws. (Fig. #27)
Note:
Gasket must be installed with access
panel.
11
Fig #24
Fig #25
Fig #26
NG
Fig #27
Minimum
rate screw
LP