INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
These instructions are supplementary to the Installation and
Operating Instructions supplied with the fi replace and should be
kept together. Refer to the Installation and Operating Instructions
for proper gas supply, safety requirements and operating
instructions
120209-12
TC42
CHALET II
BURNER KIT
INSTALLATION
INSTRUCTIONS
PART#
TC42.NG06.C
FOR TC42
TC42.NG06.C
5056.426.C1A

Advertisement

Table of Contents
loading

Summary of Contents for T&C TC42

  • Page 1 Operating Instructions supplied with the fi replace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS PART# TC42.NG06.C FOR TC42 120209-12 TC42.NG06.C 5056.426.C1A...
  • Page 2: Contents Of Package

    Contents of Package • BURNER ASSEMBLY • LOG GRATE • TC42 LOGS • EMBER MATERIAL • HARDWARE PACKAGE TC42.NG06.C 120209-12...
  • Page 3 Fig. # 5 5. Position the grate over the burner tray and attach to the fl oor with two screws through holes located behind the front legs of the grate. (Fig. # 5) GRATE INSTALLATION TC42.NG06.C 120209-12...
  • Page 4: Glowing Embers

    Ember material placement and amount will affect fl ame appearance. More ember material results in lower fl ame height. Add or remove as needed until desired fl ame affect. Fig. # 6 Ember Material Placement GRATE GLOWING EMBERS TC42.NG06.C 120209-12...
  • Page 5 Fig. # 8 LOG #2 LOG #1 Fig. #9 Fig. #10 LOG #3 LOG #4 Fig. #11 Fig. #12 LOG #5 LOG #6 Fig. #13 LOG #7 Note: Improper placement of logs will cause sooting on internal parts and glass. TC42.NG06.C 120209-12...
  • Page 6: Propane Conversion

    (Fig. #16) manufacturer's instructions supplied with the kit. Fully open the primary air shutter. Reinstall the manifold assembly CAUTION The gas supply and electrical power must be shut off before proceeding with the conversion. TC42.NG06.C 120209-12...
  • Page 7 (Fig. #19 shows NG position, Fig. # 20 shows LP position) Fig. #20 Fig. # 21 Remove the minimum rate screw located in the valve. (Fig. #21) Minimum rate screw TC42.NG06.C 120209-12...
  • Page 8 Fig #25 14. Attach the access panel to the side of the fi rebox with the previously removed screws. (Fig. #25) Note: Gasket must be installed with access panel. TC42.NG06.C 120209-12...
  • Page 9: Gas Pressure Check

    Correct gas pressure requirement: Supply Pressure Natural Gas Propane (For purpose of input adjustment) Minimum 5.0" WC 12.5" WC Maximum 13.9" WC 13.9" WC Manifold Pressure Maximum 3.8" WC 11.0w" WC Minimum 2.1" WC 5.5" WC TC42.NG06.C 120209-12...
  • Page 10: Burner Flame Adjustment

    2. Remove the log set and set aside. 3. Loosen the screw in the Primary Air Shutter. 4. Rotate the shutter to increase or decrease the amount of primary air. 5. Reassemble in reverse order. PRIMARY AIR SHUTTER TC42.NG06.C 120209-12...
  • Page 11: Replacement Parts

    #5..MAIN SUPPLY TUBE (FLEX) ..... 5019.223 #2..7 PCS LOG SET ......... 5094.42161 #6..PILOT TUBE (FLEX) ......5019.225 #3..ORIFICE, NATURAL GAS (#25) ..5022.12 #7..PROPANE CONVERSION KIT ... TC42.LPCEO1 NOT SHOWN KIT CONTENTS: #1..BURNER ASSEMBLY #3..