INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
These instructions are supplementary to the Installation and
Operating Instructions supplied with the fi replace and should be
kept together. Refer to the Installation and Operating Instructions
for proper gas supply, safety requirements and operating
instructions
160508-12
TC42
HEARTWOOD
BURNER INSTALLATION
INSTRUCTIONS
PART#
TC42.NG05.C
FOR TC42
TC42.NG05.C
5056.426.C5

Advertisement

Table of Contents
loading

Summary of Contents for T&C TC42.NG05.C

  • Page 1 Operating Instructions supplied with the fi replace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions TC42 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS PART# TC42.NG05.C FOR TC42 160508-12 TC42.NG05.C 5056.426.C5...
  • Page 2: Contents Of Package

    Contents of Package • BURNER ASSEMBLY (including pilot and manifold) • LOG GRATE • EMBER MATERIAL (one bag) • COAL CHUNKS (one bag) • VERMICULITE (one bag) • HARDWARE PACKAGE TC42.NG05.C 160508-12...
  • Page 3 Fig. # 5 5. Position the grate over the burner tray and attach to the fl oor with two screws through holes located behind the front legs of the grate. (Fig. # 5) TC42.NG05.C 160508-12...
  • Page 4 Reduce the amount used on Propane models, as too much will create soot. Fig. # 6 Embers only in this area. Embers only in this area. Fig. # 6a Embers, coal chunks and lava rock. Embers, coal chunks and lava rock. TC42.NG05.C 160508-12...
  • Page 5 LEFT FRONT LOG, #c Fig. #10 Fig. #12 Fig. #11 LOG WITH HOLE, #d RIGHT CENTER LOG, #e FRONT RIGHT LOG, #f Fig. #13 Fig. #15 Fig. #14 RIGHT BASE LOG, #g CENTER TWIG, #h CENTER BASE CHUNK, #i TC42.NG05.C 160508-12...
  • Page 6: Propane Conversion

    (Fig. #18) manufacturer's instructions supplied with the kit. Fully open the primary air shutter. Reinstall the manifold assembly CAUTION The gas supply and electrical power must be shut off before proceeding with the conversion. TC42.NG05.C 160508-12...
  • Page 7 (Fig. #20 shows NG position, Fig. # 21 shows LP position) Fig. #21 Fig. # 22 Remove the minimum rate screw located in the valve. (Fig. #22) Minimum rate screw TC42.NG05.C 160508-12...
  • Page 8 Fig #26 14. Attach the access panel to the side of the fi rebox with the previously removed screws. (Fig. #26) Note: Gasket must be installed with access panel. TC42.NG05.C 160508-12...
  • Page 9: Gas Pressure Check

    Correct gas pressure requirement: Supply Pressure Natural Gas Propane (For purpose of input adjustment) Minimum 5.0" WC 12.5" WC Maximum 13.9" WC 13.9" WC Manifold Pressure Maximum 3.8" WC 11.0w" WC Minimum 2.1" WC 5.5" WC TC42.NG05.C 160508-12...
  • Page 10: Burner Flame Adjustment

    Operating Instructions manual. 2. Remove the log set and set aside. 3. Loosen the screw in the Primary Air Shutter. 4. Rotate the shutter to increase or decrease the amount of primary air. 5. Reassemble in reverse order. TC42.NG05.C 160508-12...
  • Page 11: Replacement Parts

    FRONT RIGHT LOG (f) LOG WITH HOLE (d) RIGHT BASE LOG (g) RIGHT CENTER LOG (e) CENTER TWIG (h) FRONT RIGHT LOG (f) CENTER BASE CHUNK (i) RIGHT BASE LOG (g) CENTER TWIG (h) CENTER BASE CHUNK (i) TC42.NG05.C 160508-12...
  • Page 12 TECHNICAL SUPPORT: 1-888-715-2664 www.townandcountryfi replaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada...