SEA USER'S MANUAL
Care & Maintenance
It is important to provide the proper preventative maintenance in order to
ensure the best possible performance and reliability of the SEA. The follow-
ing maintenance procedures should be performed routinely after each use of
the equipment.
1. After each in-water training session, the SEA must be cleaned,
inspected, prepared for the next use or for storage.
2. As soon as possible after training, the SEA should be soaked thoroughly
for at least one hour in warm (not over 120ºF / 49ºC) tap water to loosen and
dissolve salt (if used in salt water) and mineral deposits. Before soaking,
remove the protective retainer cover and turn the valve to the "ON" position
to pressurize the system. This will best prevent the entrance of moisture into
the system through the second stage.
CAUtIoN:
portant to ensure that the valve is completely turned to the
"oFF" position, and the second stage purge button is not
depressed while the system is submerged or wet. Moisture
may otherwise be allowed to enter the valves and the cylinder,
which will require that the system be returned to a qualified
technician for inspection and service.
3. After the system has been properly soaked, it is important to rinse the
first stage, the second stage mouthpiece, and the openings in the second
stage front cover with a pressurized stream of water. This will remove the
salt and mineral deposits that were loosened during soaking.
4. When it has been properly soaked and rinsed, wipe the system as
dry as possible with a clean towel and gently shake the first and second
stage to dislodge any water inside them. If possible, use clean low pres-
sure air to blow out of retainer cap prior to installing the rubber retainer
cover. Re-install the rubber retainer cover when the unit is completely dry.
5. Check to ensure that the SEA valve is turned to the "OFF" position,
and depress the purge button of the second stage to ensure that the sys-
tem is completely depressurized before storing or transporting.
6. Due to the possibility of fire and exposure to extreme heat, the SEA
must be stored either completely full or completely empty. If the system is
exposed to fire while partially filled, the cylinder wall may rupture before
the internal pressure becomes great enough to burst the safety relief disc.
For this reason, Aqua Lung recommends that the cylinder be completely
emptied and the valves kept shut to prevent the entrance of moisture
before storing the system for an indefinite period.
If the SeA cylinder does not contain air, it is im-