Troubleshooting; Storage - Viper FANG 18 C User Manual

Viper fang 18 c user manual
Hide thumbs Also See for FANG 18 C:
Table of Contents

Advertisement

ENGLISH
SOLUTION/CLEAN wATEr FILTEr CLEANING
Drive the machine on a level floor.

Confirm the machine is unplugged.

Remove the transparent cover (D),then remove the filter strainer (B).Clean and install them on the support (A).

notE
The filter strainer (B) must be correctly positioned on the housing (E) of the support (A).

TrOUBLESHOOTING

prOBLEM
no power
vacuum motor does not run
Little or no solution flow
poor water pick up
do not over tighten or damage will occur.

STOrAGE

CAUTION!
if you are storing the machine in an area which can freeze, be sure both tanks and the solution plumbing are empty of
all water and dry!
switch off the appliance.

pull the mains plug out of the socket.

store the appliance in a dry place, protected from frost.

the machine storage temperature must be between 0°C and +40°C. always store the machine indoors.

14
USER MANUAL
wiring not connected correctly or bad wiring
bad brush motor
Carbon brushes worn out
wiring not connected correctly or bad wiring
bad vacuum motor
Carbon brushes worn out
bad ball valve
bad solution valve
ball valve position in need of adjustment
squeegee clogged
squeegee blades worn
squeegee not mounted correctly
vacuum hoses have a hole or are loose
vacuum hose may be clogged
drain hose stopper is loose
vacuum motor is loose
recovery tank lid is loose
recovery tank is full
float shut off is clogged
FANG 18C
CAUSE
Check the wiring or contact viper service
Contact viper service
Contact viper service
Check the wiring or contact viper service
Contact viper service
Contact viper service
Contact viper service
Contact viper service
when ball valve is in horizontal position. the
amount of solution flow is maximum
Clean debris off squeegee with damp towel
install new squeegee blades
Confirm that the squeegee assembly is se-
curely fastened to the machine and not loose
fitting
Check hose connections and make sure they
are firm. Replace hose if damaged
Check hose for debris and remove any clog
tighten drain plug
tighten vacuum motor mounting screws
Confirm the clear recovery tank lid is securely
in place
drain recovery tank
Remove float shut off from inside recovery
tank and remove any debris
SOLUTION