3. Pre Installation

This appliance must be fitted in accordance with the current
Building Regulations and by an approved HETAS registered installer.
Note: This appliance is heavy and must be handled with care.
The appliance is supplied fully assembled for a top flue arrangement.
The lid, door and internal parts can all be removed to reduce the stove
weight during installation
The paint is soft and vulnerable to marking; refer to the maintenance
section.
Chesney's stoves must be connected to a suitable chimney. Chesney's
strongly recommend using a complete and compliant chimney lining
system.
Inside the stove you will find an Installation and user manual and a pair of
Chesney's Gauntlets. The multi-fuel stoves also have an ash pan and tool.
Ventilation
Please refer to Document J section 2 (table 1) Outside Air Kits are
available please ask your stockist.
The installation of extract ventilation or other appliance that requires air for
combustion in the same area are not recommended and will effect this
.
appliance
Refer to page 12 Flue Requirements
Chesney's recommend an appropriate spillage test be conducted with all
appliances post installation.
Air inlet grilles must be so positioned that they are not liable to blockage.