1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature. When the air
conditioner is stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control. The angels of the vane are as stated above. When the air
conditioner is stopped using remote control, the vane will shift to close position.
* Above angle data is for reference only.
12.3.2 Horizontal Airflow
The horizontal airflow direction louvers can be adjusted manually by hand.
12.3.3 Quiet operation
To provide quiet operation comparing to normal operation. The Quiet operation can be active or stop by pressing
QUIET/POWERFUL button on remote control.
Once Quiet mode is active ,the unit will continuously operate in QUIET Mode until cancel the mode by pressing
QUIET/POWERFUL button on remote control.
12.3.4 Powerful operation
To cooling or heating the room faster comparing to normal operation. The POWERFUL operation can be active or
stop by pressing QUIET/POWERFUL button
When powerful operation is active, the unit will continuously operate in POWERFUL mode until cancel the mode
by pressing QUIET/POWERFUL button on remote control. Operation details are as the fig. below.
1. For cooling, soft Dry mode
Power Button pressed
D
PIPING
C
TEMP.
(COOLING)
B
A
FAN SPEED
( rpm)
Correction
Factor( )
OFF
2. For Heating mode:
Power Button pressed
D
C
PIPING
TEMP.
B
(COOLING)
A
FAN SPEED
( rpm)
Correction
Factor( )
OFF
Note: The value of A, B, C, D will change according to the indoor temperature.
Min.5'
Fast Cooling
1130 (Max)
Shi
45 seconds
20 '
-1.67
-1.00
ON
Min.5'
Fast Heating1
1270 (Max)
Shi
45 seconds
+1.00
+2
20 '
ON
remote control.
Cooling, Soft Dry
730 (Min.)
20 '
20 '
20 '
-0.25
Heating
940 (Min.)
20 '
20 '
+0.25
20 '
34
AUTO
+0.25
AUTO
+0.25