Indication Panel; Timer Control - Panasonic CS-RE9JKE Service Manual

Hide thumbs Also See for CS-RE9JKE:
Table of Contents

Advertisement

12.3.5 Automatic Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to
four minutes after power supply resumes.

12.3.6 Indication Panel

LED
POWER
Color
Green
Light ON
Operation ON
Light OFF
Operation OFF
Note:
If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer
sampling.
If Timer LED blinks, there is an abnormal operation occurs.

12.3.7 Timer control

Delay ON Timer ca be set using remote controller, the unit with timer set will start operate earlier than the setting time.
This is to provide a comfortable environment when reaching the set On time. Seventy minutes before the set time for
ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds
to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation mode.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
Timer Signal Receiving sound During Operation.
Timer Signal Receiving Sound When the Air Conditioner Stops.
TIMER
Orange
Timer setting ON
Timer setting OFF
35
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-re12jkeCu-re12jkeCu-re15jkeCs-re15jkeCu-re9jke

Table of Contents