Operating Instructions
Switch Power Filter Clean off
! Setting of the slide (1) -
upwards.
Note:
— It is advisable to switch off the -
Power Filter Clean – function
when vacuuming wet dirt with
the upholstery or the crevice
nozzles or mainly water out of a
container.
— The appliance turns itself
automatically off when the max.
liquid level has been reached.
— Switch the appliance off and
empty the container.
— Clean and dry the flat pleat
filter and the electrodes as well
as the container after finishing
wet vacuuming jobs.
NT 361 Eco TEA / NT 611 Eco TEA
Care and maintenance
Danger!
Always pull out the mains plug
when working on the suction
machine.
Replacing the flat pleated
filter or the exhaust air
filter
! Open the filter cover (1)
! Replace the flat pleated
filter (2) or the exhaust air
filter (3)
! Close filter cover, it must
audibly engage
Clean electrodes
! Unlock and remove the suction
head
! Clean electrodes
! Replace the suction head and
lock it in place
English
Fault instructions
The suction turbine does not
run
! Check the cable, plug, fuse and
socket.
! Switch on the machine.
The suction turbine switches off
! Empty the container.
The suction turbine does not
restart following emptying of
the container
! Switch the appliance off and
wait for 5 s, switch it on again
after 5 s.
! Clean the electrodes as well as
the space between them.
The suction power decreases
! Remove the parts clogging up
the suction nozzle, the suction
tube, the Power Filter Clean
handle, the suction hose or the
flat pleat filter.
! Change the paper filter bag.
! Actuate the filter
cleaner: Power Filter Clean
several times at the handle.
! Engage the filter cover
properly.
! Replace the flat pleat filter.
14
Need help?