Quick Start
Status LED's Operation Legend
TURBINE LED
BATTERY LED
GFI LED
Quick Start: DC Charge Controller for Honeywell Wind Turbine WT6500 - Rev 2.0 - 29Nov11
1.
NO LED
•
Turbine is sleeping or DC Charge Controller is off
2.
GREEN
•
Turbine is running
3.
RED
•
Turbine is stopped
4.
ONE RED BLINK
•
No Wind Speed – Turbine Voltage > 40 VDC and Wind Speed = 0 MPH for
1 minute
5.
TWO RED BLINKS
•
Turbine over current – Turbine current > 9 Amps
6.
THREE RED BLINKS
•
No turbine fault – Turbine Voltage < 5 VDC and Wind Speed > 10
MPH for 1 minute
7.
FOUR RED BLINKS
•
Turbine over voltage – Turbine Voltage > 170 VDC
1.
GREEN
•
Batteries are charged (when battery voltage stays at 55 V for a 48 V
battery system).
2.
ONE RED BLINK
•
Low battery fault – Batteries are lower than 45 V (for a 48 V battery
system).
3.
TWO RED BLINKS
•
High battery fault – Batteries are higher than 58 V (for a 48 V battery
system).
4.
THREE RED BLINKS
•
Charge over temp – Enclosure > 65°C or Heat Sink > 140°C
5.
FOUR RED BLINKS
•
Charge over current – Charge current > 24 Amps
1.
RED
•
Indicates GFI Fault
17