Honeywell DCCC6500 Quick Start Manual page 16

Dc charge controller for honeywell wind turbine model wt6500
Hide thumbs Also See for DCCC6500:
Table of Contents

Advertisement

16
Commissioning
Figure 9: Battery Configuration Switches
Quick Start: DC Charge Controller for Honeywell Wind Turbine WT6500 - Rev 2.0 - 29Nov11
1.
To configure the DC Charge Controller to a 48 VDC system (refer to figure 9) set
switch S1 to "On".
2.
Set switch S2 to "On".
3.
Set switch S3 to either "On" if using AGM batteries, or "Off" is using flooded batteries
(refer to figure 9).
4.
Turn on the following switches in the following sequence:
Battery switch
DC Charge Controller ON/OFF switch
15 Amp fused disconnect
DCCC junction box ON/OFF switch
5.
Verify turbine LED on DC Charge Controller is green.
EXPLOSION OR FIRE HAZARD
Entering battery information incorrectly may result in
explosion or fire.
Quick Start